Technical Specifications of the Kit Components
LINEA 3000 Video Keypad ( Cod: 343081)
- Technology: 2 wires
- Installation: Wall mounted with zama front and wide angle colour camera
- Illumination: White LEDs for low-light shooting range
- Configuration: Suitable for single-family or two-family installations
- Electric lock: Activation connected directly between terminals S+ and S- (18 V 4 A impulsive, 250 mA maintenance, 30 Ohm max)
- Name Tag: Illuminated with white LED
- Protection: IP54 protection grade and IK10 robustness grade
- Height: 190 mm
- Width: 100 mm
- Depth: 26.65 mm
- Calls: 2
- System Type: 2 wires
- Recommended Installation Height: 160-165cm
- Operating Temperature: -25/+70°C
- Resolution: 330 TV Lines H
Video intercom CLASS 100V16E ( Cod: 344672)
- Technology: 2-wire hands-free with teleloop
- Display: 5” color LCD
- Commands:
- 2 physical buttons for answering and ending calls
- 3 touch buttons for electric lock, stair lights and activation of external unit/scrolling
- 4 configurable touch buttons for additional functions
- Adjustment: Side lever for color, brightness, display contrast, audio volume and ring tone
- Signal LED: For call exclusion
- Installation: Outside the wall with included bracket or on a table with support purchased separately (Code 344692)
- Configuration: Required for the professional studio function
- Voltage: 20/27V
- Height: 165 mm
- Width: 164 mm
- Depth: 20.5 mm
- Maximum Cable Section: 2x1 mm²
- System Type: 2 wires
- Recommended Installation Height: 160-165cm
- Operating Temperature: -5/+40°C
- Resolution: 800 x 480
- Wi-Fi: No
- Teleloop: Yes
- Color: White
BUS-SCS Power Supply in 6 DIN Modular Case ( Cod: 346050)
- Compatibility: 2-wire audio and video systems in 6 DIN modular housing
- Power supply: 110 - 240 V AC @ 50 – 60 Hz
- Outputs:
- Two safety extra low voltage power supplies (TK BUS, PI BUS and SCS; terminal 1 - 2)
- Alternating, non-concurrent use
- Video Adapter: Integrated, avoids the use of item 346830
- Additional Use: Additional power supply for internal or external stations
- Protection: Against overload and short circuit, SELV double insulation
- Installation: In accordance with current regulations, only in switchboards designed for DIN devices, internal environments
- Switch: Omnipolar with separation >= 3 mm, close to the power supply
- Category: CAT II 2500 V, requires additional protection from transient voltages
- Integrated Fuse: F1 T 3.15A 250V
- Dimensions: Space requirement: 6 DIN modules
PRI (AC Power Input):
- Nominal Voltages: 110 – 240 V
- Nominal Currents: 730 – 400 mA
- Working Frequency Range: 50 – 60 Hz
- Power Consumption at Full Load: 40 W max
- Power Dissipation: 8 W max
- Full Load Efficiency: 80% typ
- Standby power: < 1 W
- Operating Temperature: -10 – +55°C
BUS TK, BUS PI, SCS:
- Nominal Voltage: 27V DC
- Rated Current: 1.2A
- Rated Power: 32.4W
1–2:
- Nominal Voltage: 28.5V DC
- Rated Current: 1.2A
- Rated Power: 34.2W
Power Supply Installation:
- Always install in appropriate containers
- Protect from dripping and splashing water
- Do not block the ventilation openings
- Use a double pole switch with separation >= 3 mm near the power supply
- Do not solder the ends of the conductors into the terminals
Relay Module for Electric Locks Not Managed by BUS ( Cod: 346250)
- Function: Gate opening to be combined with the external push-button panels provided
- Compatibility: Locks NOT managed by BUS via the external unit
- Contact Type: NO-NC
- System Type: 2 wires